by razman.ayop | Nov 27, 2019 | Research Guidance
Scope can easily shown you the result of the simuilation. However, it is not clear when the graph from the scope is transfer to the Word document. Here is the step to properly plot graph from Simulink simulation. Add “To workspace” block into the...
by razman.ayop | Nov 24, 2019 | Research Guidance
In MATLAB/Simulink, a block from a library cannot be shared with a different library. Therefore, it is better to open a specific library for power system called the “Power System Library” This library is able to interface with Simulink Library...
by razman.ayop | Nov 20, 2019 | Research Guidance
Particle Swarm Optimization Maximum Power Point Tracking Boost Converter. Link: https://www.mathworks.com/matlabcentral/fileexchange/73318-pso-mppt-boost-converter?s_tid=prof_contriblnk PV module requires MPPT converter to obtain maximum power. However, during partial...
by razman.ayop | Nov 15, 2019 | Appointed
Location: DK4, P19. Time: 2 p.m. – 5 p.m. Type: Task Force Lead: Dr. Jasrol (Director of Power Division) Food Distribution to the students by the volunteers. Volunteers open the drinking water from the box. Students during workshop. Students receives a sandwich...
by razman.ayop | Nov 11, 2019 | Research Guidance
X-Y Plotter with Animation and Reference Curve Link: https://www.mathworks.com/matlabcentral/fileexchange/73284-x-y-plotter?s_tid=prof_contriblnk Plot X-Y. Similar to XY Graph in Simulink/Sink. But, the animation can be controlled to easily see the movement of the...
by razman.ayop | Nov 2, 2019 | Research Guidance
The amplifier circuit function is to increase the sensitivity of the measurement. It is an additional circuit. Without it, the sensor still function. Function of amplifier circuit: To increase the Vsensor. This improve the sensitivity of the measurement. To limits the...
by razman.ayop | Nov 2, 2019 | Research Guidance
The recommended current sensor is the LEM LA55. It is a closed loop hall effect sensor capable of measuring DC and AC. It can measure up to 50 A or 100 A (2 different design). However, for this tutorial, the design is based on 50 A. The number of primary turns, Npri,...
by razman.ayop | Oct 9, 2019 | Community Service
PV Toolkit (1) PV Toolkit (2) PV Toolkit (3) PV Toolkit (4) PV Toolkit (5) PV Toolkit (6) PV Toolkit (7) PV Toolkit (8) PV Toolkit (9) Component Rating Function Quantity Per Price (RM) Price (RM) PV Panel 21V 3A 50W Supply Energy 1 389.90 389.90 Battery 12V DRY Store...
by razman.ayop | Oct 2, 2019 | Research Guidance
The recommended voltage sensor is the LV25 from LEM. It is a closed loop sensor. capable of measuring DC and AC with the maximum voltage of 500 V. Do not use this sensor if the voltage is more than 500 V. Rpri depend on the maximum Vmeasure: Rpri = 100 Vmeasure The...
by razman.ayop | Oct 2, 2019 | Research Guidance
How to Set the Sample Time for Power Converter Click Simulation (Upper Site)> Model Configuration Parameter>Solver>Solver Option=Variable Step> Additional Options: Max step size= 1e-6 1e-6 is the standard. The minimum “Max step size” is: Max Step Size...